Adding a Meter to a Four-Wire on the Canvas (Pre-Populated Port Viewer)
You can add a meter to a four-wire that has been dragged to the canvas, to form a pre-populated Port Viewer.
You can find a list of the available four-wires under the four-wire tab of the palette in Configure Canvas. All the four-wire ports present in the system configuration are displayed under the four-wires tab, except four-wire ports configured as either monitors or idents.
You cannot add a meter to an unpopulated (empty) Port Viewer, even after you have assigned a four-wire to that viewer. You can meter activity on this kind of viewer, however, by using the dynamic (cursor) meter (see Cursor Meter).
For more information about pre-populated and unpopulated (empty) Port Viewers, see Idents and Monitors (Split Label Ports).
To add an audio meter to a four-wire on the canvas (pre-populated Port Viewer):
-
In Configure Canvas > four-wire tab, add the four-wire to the canvas.
-
Select the Other tab. The meter control is displayed in the list of available items.
-
To add an input meter, drag the meter control to the left-hand side of the pre-populated Port Viewer.
The meter is displayed on the left-hand side of the viewer:
-
To add an output meter, drag the meter control to the right-hand side of the pre-populated Port Viewer.
The meter is displayed on the right-hand side of the viewer:
You cannot perform output level metering on ports that are not on the same system as the LMC-64 card.